Data centers keep getting denser, hotter, and more compliance-driven—and the BICSI Data Center Design Consultant (DCDC) badge is the industry’s shorthand for “yes, I can design that.” Below you’ll find a 10-question, 2025-aligned mini-quiz plus a roadmap for translating practice points into a guaranteed first-attempt pass.
10 Quick-Fire Practice Questions (2025 Blueprint)
# | Question | Choices |
---|---|---|
1 | The maximum ∆T (air-in to air-out) recommended for a cold-aisle containment system per BICSI 002-2023 is: | A) 10 °F (5.6 °C) B) 18 °F (10 °C) C) 27 °F (15 °C) D) 35 °F (19 °C) |
2 | For a data-center fire-suppression system using clean agent, NFPA 2001 requires minimum agent hold-time of: | A) 5 min B) 10 min C) 1 min D) 30 sec |
3 | A 1.2 MW IT load runs at 2.0 PUE. What is the facility’s total power requirement? | A) 1.2 MW B) 1.44 MW C) 2.4 MW D) 3.2 MW |
4 | For Tier III concurrent maintainability, the UPS system must provide N + __ redundancy. | A) 1 B) 2 C) 0 D) 1.25 |
5 | The minimum hot-aisle width for a 1 200 mm-deep cabinet per BICSI is: | A) 900 mm B) 1 200 mm C) 1 500 mm D) 1 800 mm |
6 | Which cooling technology offers the lowest W/ton in a warm-humid climate? | A) Air-cooled DX CRAC B) Water-cooled chiller + CRAH C) Evaporative direct cooling D) Rear-door heat exchangers |
7 | The recommended maximum voltage drop for 48 Vdc busway feeders in a data center is: | A) 1 % B) 2 % C) 3 % D) 5 % |
8 | Modular “containerized” data-center units typically fall under which Building Construction risk category per ASCE 7? | A) I B) II C) III D) IV |
9 | According to TIA-942-B, the minimum number of diverse entry points (POP rooms) for a Tier IV facility is: | A) 1 B) 2 C) 3 D) 4 |
10 | Which airflow management metric best predicts rack-level hotspots? | A) ∆T across CRAH coils B) Rack inlet temperature deviation C) Return-air humidity D) PUE trending |
Answer Key
1-B | 2-B | 3-C | 4-A | 5-B | 6-C | 7-B | 8-B | 9-B | 10-B
Scoring:
-
8–10 correct: You’re exam-day ready—move to a full 100-question timed mock.
-
5–7 correct: Review containment deltas, Tier redundancy maths, and busway voltage-drop tables.
-
<5 correct: Start with the cooling-power, containment, and TIA-942 core chapters.
Need a deeper technical primer first? Dive into Power & Cooling Fundamentals Every BICSI DCDC Candidate Must Master for airflow math, PUE tricks, and containment dos & don’ts.
Convert Your Practice Score into a Passing Score
-
Timed Mock Engine – Four 50-question drills that mirror BICSI’s Pearson VUE interface.
-
Adaptive Lab Replicas – Size CRAH coils, calculate W/ton, and lay out busway sections in our live sandbox.
-
One-to-One Mentor Calls – Walk through Tier math, UPS topologies, and containment design with a DCDC-certified engineer.
-
24 × 7 WhatsApp War-Room – Panic-hour help when your PUE math won’t balance.
-
Pay-Only-After-You-Pass Guarantee – No tuition due until BICSI emails you “PASS.”
Ready to Earn the DCDC Badge on Your First Try?
📲 Grab a free 25-question DCDC PDF or book a 15-minute roadmap call: https://certfastpass.net/contact/
Try smarter. Pass faster. Design cooler—with Cert Fast Pass.
Leave a Reply